Loading... Please wait...

Vulkem 116 for Crack and Expansion Repair Caulk

Hover over image to zoom

  • 116 CAULK FOR REPAIR OF EXPANSION JOINTS, CONTROL JOINTS, BREAK JOINTS AND CRACKS ON CONCRETE
  • Horizontal crack on exposed aggregate
  • Horizontal crack on exposed aggregate repaired with 45-SSL caulk and finish sand
  • Vertical crack on a foundation wall repaired with 116 Caulk
  • Vertical crack on a foundation wall repaired with 116 Caulk and tooled with soap on finger
Tremco
$12.25
SKU:
TR-VULK116

 Product Description

116 Caulk for repair of expansion joints, control joints, break joints and cracks on concrete

Description:

Vulkem 116 is a one-part moisture-curing, gun-grade polyurethane sealant. Vulkem 116 is durable, flexible and offers excellent performance in moving joints. Vulkem 116 does not require a primer on most construction materials. Product meets ASTM C920-98 and CAN/CGSB 19.13-M87. Vulkem 116 Polyurethane Sealant for Horizontal and vertical Use 

Basic Uses:

Vulkem 116 is an excellent general purpose sealant designed for use in precast, masonry, window frame perimeters and similar types of construction joints. Vulkem 116 is suitable for continual immersion in water. Vulkem 116 is designed for exterior and interior use.

Limitations:

• Do not apply over damp or contaminated surfaces.
• Use with adequate ventilation.

Packaging: 
10.1 US fl oz cartridges. (30 Tubes per box)


Color: Limestone

Applicable Standards:
Conforms to U.S. Federal Specification TT-S-00230C, Type II, Class A and ASTM C920, Type S, Grade NS, Class 25, Use NT, M, T, A, I, O, and CAN/CGSD-19.13, MCG-2-25-B-N. Conforms to USDA approval standards.
 

Installation:

Joint Design: May be used in any vertical or horizontal joint designed in accordance with accepted architectural/engineering practice. Joint width should be 4 times anticipated movement, but not less than ¼ inch (6.4mm) wide. Movement should not exceed 25% of the minimum joint width.

Joint Dimensions:
For joints ¼ inch (6.4mm) to ½ inch (12.7mm) wide, the width to depth ratio should be equal. Joints ½ inch (12.7mm) wide or greater should have a sealant depth of ½ inch (12.7mm). Minimum joint size is ¼ inch by ¼ inch (6.4mm by 6.4mm).
 

Surface Preparation:
For good adhesion, the joint interface must be sound, clean and dry. Depending on the substrates, or presence of form release agents, masonry waterproofing, dust, loose mortar or laitance, architectural paints or finishes, the joint surface may require a thorough wire bushing, grinding, sandblasting, solvent washing and/or primer.


Tooling & Cleaning:
Use dish soap to tool with fingers. Tooling is recommended immediately after application to insure firm, intimate contact with the joint interface. Dry tooling is preferred. Excess sealant and smears adjacent to the joint can be carefully removed with Xylol or Toluol before sealant cures

CAUTION! 

Not intended for use by persons with pre-existing lung disorders or breathing problems or by those who have had a reaction to iscoyanates. Do not breathe vapors. Reports have associated repeated and prolonged occupational exposure to solvents with permanent brain and nervous system damage. Contains less that 115 gm of VOC per liter less water and less exempt solvent. (New Jersey statement: Contents of this container contain less that 1.0 pounds per gallon of VOC less water). Solvent contained is photochemically reactive.

Vapor harmful. May cause skin, eye and lung irritation and allergic respiratory reaction. Potential sensitizers. Long term overexposure to xylene may cause adverse kidney, liver or fetal development effects. Avoid ingestion, inhalation of vapors and contact with skin, eyes and clothing. Use only in well ventilated areas. If vapor concentration is unknown or exceeds exposure limits (e.g. TVs/PELs), wear suitable respiratory protection as indicated on the MSDS. Wear suitable eye, face and hand protection and other protective apparel. For additional health and safety information read the current MSDS carefully before using this product.

First Aid:
Get medical attention immediately for any significant overexposure.

Inhallation:
Leave area to breathe fresh air. Avoid further overexposure.


Eyes:
Flush immediately with running water for 15 minutes and get medical attention.


Skin:
Wash thoroughly with hand cleaner followed by soap and water. Get medical attention immediately if rash or other disorders develop.


Ingestion:
Call nearest Poison Control Center or physician. DO NOT INDUCE VOMITING.

 

DOCUMENTS (PDF format):

   

 Product Videos

How to repair expansion joints in concrete - www.SealGreen.com 800-997-3873
  • How to repair expansion joints in concrete - www.SealGreen.com 800-997-3873
    How to repair an expansion joint in concrete. In this video we...
  • How to Repair a Crack in Concrete - www.SealGreen.com 800-997-3873
    How to repair a crack in concrete shows step by step how to do...

 Find Similar Products by Category

You Recently Viewed...

 

What's News

newsletter

Copyright 2017 SealGreen. All Rights Reserved.
 Sitemap | Bigcommerce Premium Themes by PSDCenter


Click the button below to add the Vulkem 116 for Crack and Expansion Repair Caulk to your wish list.